Battery pack / fuel cell / e-Powertrain

DC source/sink

Single-Channel System

I-TS-3840: The I-TS-3840 is a DC source/sink with one channel that can be supplemented with selected options. The design is standardized, the available options are provided in the already created designs.

DC-Quelle/Senke Hochleistungs-DC-Test und -Simulation

 

Our high-performance test system I-TS (Infeed test system) is ahigh dynamic, bidirectional DC power supply with continuous and seamless transition from source to sink operation. The outstanding performance is the basis for a wide range of applications in the automotive, hydrogen and laboratory sectors.

Standard features

Typical applications

Performance hyperbole

Technical data

Typ I-TS-3840

AC mains voltage /
AC mains frequency

380V 3/PE ± 10 %;
400V 3/PE ± 10 %
50 Hz ± 5 %; 60 Hz ± 5 %

Measurement accuracy

Voltage: 16 Bit ADC // Current: 16 Bit ADC

Control accuracy

Voltage: 0,1 % fs // Current: 0,1 % fs

Residual ripple

Voltage ≤ 0.1 % eff. fs
Current ≤ 0.1 % eff. fs

Voltage tolerance dynamic
(0-100 % INom in 3 ms)

Battery tester< 3% fs
Battery emulator < 1% fs

Short circuit performance

Short circuit proof:
Systems up to 600 A: Icw: 3 kA
Systems with 1000 A: Icw: 8 kA
Systems with 1200 A: Icw: 15 kA

Permissible environmental conditions:
Storage as per EN 60721-3-1
Transport as per EN 60721-3-2
Operation as per EN 60721-3-3

1K21 / 1M11, +5 bis +40 °C
2K12 / 2M4, -45 bis +70 °C
3K22 / 3M11, +5 bis +40 °C

Cooling method

air cooling (IP20)
water cooling (IP54)

Safety of machinery -
Safety-related parts of control systems

EN ISO 13849-1
EN ISO 13849-2

Safety of machinery

EN 60204-1 Exception:
• Sec. 11.3 Protection type see Techn. Data
• Sec. 13.2 Identifi cation of conductors

EMC Standards

EN 61000-2-4 Klasse 3
EN 61000-6-2
EN 61000-6-4 bzw.
EN 55011 (Tab. 2)
EN 61800-3 Kat.C2 (A1)

Available types

Type
I-TS-3840- 1500-260-800
I-TS-3840- 1500-400-800
I-TS-3840- 1200-320-1200
I-TS-3840- 1200-650-1200

max. Voltage in V

10 - 1500 V

10 - 1500 V

10 - 1200 V

10 - 1200 V

Power in kW

260

400

320

650

Current in A

± 800

± 800

± 1200

± 1200

Current rise time at 0.5x UNenn 10 % - 90 % in ms

< 1,4

< 1,4

< 1,0

< 1,0

Internal resistance

-19 mΩ – 1875 mΩ

-19 mΩ – 1875 mΩ

-10 mΩ – 1000 mΩ

-10 mΩ – 1000 mΩ

Subject to technical changes

We will be happy to check your requirements/specification for feasibility.

Brochure as PDF

Learn more!