Battery pack / fuel cell / e-Powertrain

DC source/sink

Type I-TS-3870 & MI-TS-3871

I-TS-3870: Single-channel system for testing and simulation of batteries, fuel cells and powertrains. One output with up to 1200 V and 1200 A. Maximum power in single operation 650 kW, up to 2.6 MW in parallel operation.

MI-TS-3871: Multi-channel system for energy-saving tests and simulations. Two or four outputs, up to 1200 V and 1200 A per output (without galvanic isolation between the DC outputs.

DC-Quelle/Senke Hochleistungs-DC-Test und -Simulation

Typical applications

Features and equipment

Safety equipment

Interfaces (partly optional)

General properties

Our options (excerpt)

Overload variant

Technical data

Type I-TS-3870 & MI-TS-3871

Input voltage /
Input frequency

380 / 400* / 440 / 480 / 500 / 690 V ± 10 %,
3-phase, PE, 50 / 60 Hz ±5 %

Measuring resolution

Voltage: 16 bit ADC
Current: 16 bit ADC

Control accuracy

Voltage: 0.1 % fs
Current: 0.1 % fs

Voltage Ripple

≤ 0,1 % eff. fs

Current Ripple

≤ 0,1 % eff. fs

Voltage tolerance
dynamic (0-100 % I Nom in 3 ms)

Battery tester < 3%
Battery simulator < 1%

Short-circuit behaviour

Systems up to 600A: Icw < 3 kA
Systems > 600A: Icw < 8 kA

Ceiling distance min.

300 (standard, IP20)

Permissible environmental conditions: Storage according to EN 60721-3-1
Transport according to EN 60721-3-2
Operation according to EN 60721-3-3

1K21 / 1M11, +5 to +40 °C
2K12 / 2M4, -45 to +70 °C
3K22 / 3M11, +5 to +40 °C

Line-up

Premises with restricted access
Installation on non-combustible floor

Protection class

IP20 according to IEC 60529
(more on request)

Security

EN ISO 13849-1

Security

EN 62040

EMC

EN 61000-2-4 Mains disturbances
EN 61000-6-2 Noise immunity
EN 61000-6-4 Emitted interference
EN 61800-3 Cat C2 (A1) Variable-speed
electric drives

*Standard 400 V

Exemplary types

Typ
I-TS-3870-120
I-TS-3870-300
I-TS-3870-600
I-TS-3870-800
I-TS-3870-1000
I-TS-3870-1200

DC voltage [V]

120

300

600

800

1000

1200

max. Output

Depending on type, between 60 and 160 kW

Depending on type, between 60 and 160 kW

Depending on type, between 60 and 500 kW

Depending on type, between 100 and 500 kW

Depending on type, between 60 and 500 kW

320 kW, 650 kW

DC current [A]

  • ± 200
  • ± 600
  • ± 1000
  • ± 200
  • ± 600
  • ± 1000
  • ± 200
  • ± 600
  • ± 1000
  • ± 200
  • ± 600
  • ± 1000
  • ± 200
  • ± 600
  • ± 1000
  • ± 600
  • ± 1200

Current rise time at UNom 10 % - 90 % (ms)

< 1

< 1

< 1

< 1

< 1,3

< 1,0

Subject to technical changes

We will be happy to check your requirements/specification for feasibility.

Brochure as PDF

Brochure 1200 V, 1200 A as PDF

Learn more!

You want to know more about our products? We will be happy to send you more information by e-mail!