.gk-techmax-width:900px.gk-tech h2margin:2em 0 .5em;padding-bottom:.2em;border-bottom:2px solid #1F4E79.gk-tech h3margin:1.3em 0 .3em.gk-tech pline-height:1.6;margin:.5em 0.gk-tech tableborder-collapse:collapse;width:100%;margin:1em 0;font-size:.95em.gk-tech th,.gk-tech tdborder:1px solid #d5d9e0;padding:8px 10px;text-align:left;vertical-align:top.gk-tech thbackground:#1F4E79;color:#fff.gk-tech tbody td:first-childfont-weight:600.gk-calloutborder-left:4px solid #1F4E79;background:#f5f8fc;padding:14px 18px;margin:1em 0.gk-ctaborder:1px solid #1F4E79;background:#f5f8fc;padding:16px 20px;margin:1.5em 0.gk-teamcolumns:2;margin:.5em 0.gk-team limargin:.2em 0

DC Source/Sink Technology

A DC source/sink is a bidirectional testing and simulation system capable of both feeding DC electrical power in a specific direction (source) and drawing it in a controlled manner (sink). Gustav Klein develops and manufactures such systems under the name “Infeed Test System DC” for the testing and simulation of batteries, fuel cells, and electric powertrains.

As an independent manufacturer with a high degree of vertical integration, Gustav Klein supplies these systems on a custom basis (engineer-to-order)—ranging from standard single-channel solutions to systems in the megawatt range—and provides worldwide service throughout the entire system lifecycle.

DC Source and DC Sink: The Two Basic Functions

DC Source: The system supplies a defined DC voltage and a defined DC current to the device under test and functions as a controllable power source—for example, to simulate battery charging or powering a powertrain.

DC Sink (Sink): The system draws electrical energy from the device under test and behaves like a controllable load—for example, to simulate the discharge of a battery or the recuperation (braking energy recovery) of a drive.

Bidirectional operation: A bidirectional system combines both functions. Thanks to the seamless and highly dynamic transition between source and sink modes, complete charging and discharging cycles (e.g., WLTP driving profiles or pulse-power tests) can be run fully automatically on the test benches without any manual reconfiguration.

The “Infeed Test System DC” (I-TS) refers to the entire system consisting of a source and a sink; an I-TS can operate bidirectionally.

CharacteristicDC SourceDC sink (Sink)
Power DirectionPower Input to the Test SpecimenPower drawn from the test specimen
Behavior During the TestControllable Energy SourceControllable load
Typical ReplicaCharging / ReplenishingUnloading / Recovering
Phase in the test cycleCharging and operating phaseDischarge and braking phase

Bidirectional Operation and Fields of Application

Testing of Battery Modules and Battery Packs (Cycler / Pulse Power Test)

Testing during the development stage, type testing, long-term testing (e.g., according to WLTP), and end-of-line (EoL) testing. Thanks to the seamless transition between source and sink modes and the DC bus in multi-channel systems, they are ideally suited as energy-efficient battery testers. Overload-capable variants really shine in this application.

Battery simulation / battery emulation

The systems simulate the behavior of a real EV battery in test environments so that, for example, inverters or complete electric powertrains can be tested under realistic conditions without having to use a real battery.

Testing of Large-Scale Battery Storage Systems & Battery Containers

This field encompasses the testing, charging, and discharging of complete, large-volume energy storage systems (e.g., container-based solutions for grid services or industrial applications). Since enormous amounts of energy must be handled for this purpose, specialized systems such as the I-TS-3873 are used. In parallel operation, this system achieves a system output of up to 5 MW. A key efficiency advantage (MI-TS multichannel systems): When testing multiple large batteries or battery modules, energy can be transferred directly and highly efficiently between channels via an internal DC bus (e.g., test object 1 discharges into test object 2). This reduces the load on the AC grid, bypasses limited grid connections, and results in massive energy cost savings, since the DC current does not need to be converted to AC.

Fuel Cell Testing

Used during the development stage, for type testing, conditioning, as well as for end-of-life (EoL) and long-term testing. The I-TS serves as a highly dynamic, stable electrical load with low current ripple. To protect the fuel cell, a diode can be integrated for pure load operation.

Powertrain Testing & DC Motor Testing

Specialized testing of electric powertrains and electric motors; in the case of large-scale systems (such as the I-TS-3873), this also includes testing for extremely high power outputs in heavy-duty applications. In multi-channel systems, energy can be circulated within the loop during recuperation.

Electrolyzer Test & Test Power Supply

Testing and validating electrolysers for hydrogen production. The MI-TS-3873 system, for example, is specifically designed for testing entire stacks of electrolysers.

Testing of DC Charging Stations & Megawatt Charging (MCS)

The I-TS simulates the vehicle battery on the charging technology test bench to verify the reliability, fault injection, and communication capabilities of charging systems. Larger versions are “MCS-Ready” for megawatt-level charging of heavy-duty commercial vehicles.

Supplementary & Special Applications

  • HiL (Hardware-in-the-Loop) test bench for DC/DC converters: The DC channels function simultaneously as both a source and a load to precisely test DC/DC converters with or without integrated galvanic isolation.
  • Testing of Electrical Components & Assemblies: Testing and test power supply for components such as contactors, fuses, circuit breakers, switches, or penthouse assemblies.
  • Power Supply for Trains: Providing power to trains for maintenance purposes directly at Deutsche Bahn's ICE facilities.

System Family and Performance Classes

SystemBrief DescriptionProduct SeriesPerformance Data (Manufacturer Specifications)
I-TS-3840A standardized single-channel system with air cooling, galvanic isolation, and a rugged design that can be supplemented with selected options (e.g., IP54 water cooling).Predefined StandardPower: 260 kW to 650 kW; Voltage: 1,200 V or 1,500 V DC; Current: 800 A or 1,200 A (per channel); up to 2.6 MW in parallel operation
I-TS-3842Air-cooled single-channel system with high voltage dynamics (rise time 250 V/ms), very high measurement accuracy (up to 0.03% fs), and standard overload capability (30 s every 10 min).Predefined StandardPower: 60 kW to 550 kW (rated power) / up to 660 kW (peak power during overload); Voltage: 300 V to 1,500 V DC; Current: 600 A to 1,200 A (per channel)
I-TS-3872 / -SiCState-of-the-art, liquid-cooled DC source/sink (IP54) as standard; now also available with silicon carbide (SiC) technology for higher efficiency, optimized power density, and significantly reduced noise; flexible operation in single, parallel, or serial configurations.Premium StandardPower: 300 kW to 880 kW (SiC variants with 375 kW and 750 kW planned); Voltage: up to 1,500 V DC (SiC up to 1,200 V DC); Current: up to 2,000 A in parallel operation (2× ±1,000 A in single operation)
I-TS-3870 / -olHighly customizable single-channel system with a wide variety of selectable power ratings, voltages, currents, and protection classes (IP20 to IP54); the OL version features enhanced overload capacity.Customizable product seriesPower: 60 kW to 650 kW in single-unit operation (up to 2.6 MW in parallel operation); Voltage: 300 V to 1,500 V DC; Current: 600 A to 1,200 A
MI-TS-3871 / -olInnovative multichannel system (2 or 4 outputs without internal galvanic isolation) with energy-saving internal power balancing via the DC bus; the OL version features enhanced overload capacity.Custom product seriesPower: 60 kW to 650 kW total power; Voltage: 300 V to 1,500 V DC; Current: 600 A to 1,200 A per output
I-TS-3873Custom high-power system for extremely demanding “heavy-duty” applications such as battery containers, large-scale storage systems, electrolyzer stacks, and megawatt charging (MCS) for commercial vehicles; 1, 2, or 4 channels.Custom Product SeriesPower: 600 kW to 2,400 kW in single-unit operation (up to 5 MW in parallel operation); Voltage: constant up to 1,500 V DC; Current: ±2,000 A per channel

Availability, Vertical Integration, and Service

  • High level of vertical integration: In-house development and manufacturing (Schongau / Inzing).
  • Design in compliance with standards; quality and environmental management in accordance with ISO 9001 and ISO 14001.
  • Deutsche Bahn's Q1 supplier status as proof of delivery capability in a systemically important environment.
  • Custom design (Engineer-to-Order) and worldwide service throughout the entire product lifecycle.

Technical Responsibility: Test & Simulation Systems Development Team, Gustav Klein GmbH & Co. KG.

Test and Simulation Systems Team

  • Management: Martin Dlauhy
  • Vice President / Head of Global Sales: Bernhard Rill
  • Sales Director – High-Performance Test Systems: Michael Reith
  • Account Manager – High-Performance Test Systems: Matthias Hutter
  • Head of Development: Robert Holderried
  • Head of Application Engineering: Markus Siebachmeyer
  • Service Manager: Johann Schleich
  • Marketing: Melanie Bissle

Frequently Asked Questions (FAQ)

What is the difference between a DC source and a DC sink?

A DC source supplies a specified DC voltage and a specified DC current to the device under test and functions as a controllable power source. A DC sink absorbs electrical energy from the device under test and functions as a controllable load. A bidirectional system combines both functions in a single device.

What does bidirectional operation mean in the context of a DC source/sink?

Bidirectional operation means that the same system can both supply (source) and draw (sink) energy. This allows for complete charging and discharging cycles without having to switch between the two operating modes.

For which applications are Gustav Klein's DC source/sink systems suitable?

The systems are used for testing and simulating batteries, fuel cells, and electric powertrains. They cover a wide power range, from standard single-channel solutions up to the megawatt range.

Does Gustav Klein manufacture custom DC source/sink systems?

Yes. Gustav Klein builds the systems as engineer-to-order projects with a high degree of in-house production, based on its own development and manufacturing capabilities. The systems are managed in accordance with ISO 9001 and ISO 14001 and are serviced worldwide throughout their entire service life.

Are you planning a testing or simulation system for batteries, fuel cells, or powertrains? The Test & Simulation Systems team at Gustav Klein can advise you on the appropriate design and construction.

Mr. Michael Reith – Sales Director, High-Performance Test Systems · Tel. +49 8861 209-254 · Cell +49 151 42265769 · michael.reith@gustav-klein.com
Mr. Matthias Hutter – Account Manager, High-Performance Test Systems · Tel. +49 8861 209-270 · Cell +49 151 42265775 · matthias.hutter@gustav-klein.com

{ "@context": "https://schema.org", "@type": "FAQPage", "mainEntity": [ { "@type": "Question", "name": "Was ist der Unterschied zwischen DC-Quelle und DC-Senke?", "acceptedAnswer": "@type": "Answer", "text": "Eine DC-Quelle speist definierte Gleichspannung und definierten Gleichstrom in den Prüfling ein und verhält sich wie eine steuerbare Energiequelle. Eine DC-Senke nimmt elektrische Energie aus dem Prüfling auf und verhält sich wie eine steuerbare Last. Ein bidirektionales System vereint beide Funktionen in einem Gerät." }, { "@type": "Question", "name": "Was bedeutet bidirektionaler Betrieb bei einer DC-Quelle/Senke?", "acceptedAnswer": "@type": "Answer", "text": "Bidirektionaler Betrieb bedeutet, dass dasselbe System Energie sowohl einspeisen (Quelle) als auch aufnehmen (Senke) kann. Dadurch lassen sich vollständige Lade- und Entlade-Zyklen abbilden, ohne zwischen zwei Betriebsarten umbauen zu müssen." }, { "@type": "Question", "name": "Für welche Anwendungen eignen sich DC-Quelle/Senke-Systeme von Gustav Klein?", "acceptedAnswer": "@type": "Answer", "text": "Die Systeme werden für den Test und die Simulation von Batterien, Brennstoffzellen und elektrischen Antriebssträngen eingesetzt. Sie decken einen weiten Leistungsbereich von der Einkanal-Standardlösung bis in den Megawattbereich ab." }, { "@type": "Question", "name": "Fertigt Gustav Klein DC-Quelle/Senke-Systeme kundenspezifisch?", "acceptedAnswer": "@type": "Answer", "text": "Ja. Gustav Klein realisiert die Systeme als Engineer-to-Order-Projekte mit hoher Fertigungstiefe aus eigener Entwicklung und Fertigung. Die Systeme sind nach ISO 9001 und ISO 14001 gemanagt und werden weltweit über ihre gesamte Lebensdauer serviciert." } ] }