Battery pack / fuel cell / e-Powertrain

DC source/sink

Multi-Channel System – overload

MI-TS-3871-ol: Multi-channel system for energy-saving tests and simulations. Two or four outputs, up to 1500 V and 1200 A per output (without galvanic isolation between the DC outputs // Maximum values for voltage, current and number of output channels depending on the specific configuration).

Our high-performance test system MI-TS (Multichannel Infeed test system – overload) is a multi-channel, highly dynamic, bidirectional DC power supply with continuous and seamless transition from source to sink mode. Thanks to its multi-channel capability and outstanding performance, the MI-TS is the ideal test system for a wide range of applications in the automotive, hydrogen and laboratory sectors.

The MI-TS-3871-overload version of our multichannel Infeed test system enables a short-term overload at the DC output and also offers the option of parallel output channels. This means that
certain operating points outside the nominal range can be approached and thus requirements in the test sequence can be fulfilled by the MI-TS. The technical data of the DC converter in terms of output voltage and output current remain unchanged. However, a nominal output load up to 50 % higher is available for a maximum of 60 s. The subsequent regeneration time (≤ nominal load) is 5 times the overload time.

Standard features

Safety features

Interfaces

Options (extract)

Typical applications

Technical data

Type MI-TS-3871-ol

AC mains voltage /
AC mains frequency

380 / 400 / 440 / 480 / 690 V ± 10 %,
3-phase,, PE, 50 / 60 Hz ±5 %

Measurement accuracy

Voltage: 16 Bit ADC // Current: 16 Bit ADC

Control accuracy

Voltage: 0,1 % fs // Current: 0,1 % fs

Residual ripple

Voltage: ≤ 0.1 % eff. fs
Current: ≤ 0.1 % eff. fs

Voltage tolerance
dynamic (0-100 % INenn in 3 ms)

Battery tester< 3% fs
Battery emulator < 1% fs

Short circuit performance

Short circuit proof:
Systems up to 600 A: Icw: 3 kA
Systems with 1000 A: Icw: 8 kA
Systems with 1200 A: Icw: 15 kA

Permissible environmental conditions:
Storage as per EN 60721-3-1
Transport as per EN 60721-3-2
Operation as per EN 60721-3-3

1K21 / 1M11, +5 bis +40 °C
2K12 / 2M4, -45 bis +70 °C
3K22 / 3M11, +5 bis +40 °C

Cooling method

Cooling method Enforced air cooling (IP20, IP21, IP23) // enforced water cooling (IP54)

Safety of machinery -
Safety-related parts of control systems

EN ISO 13849-1
EN ISO 13849-2

Safety of machinery

EN 60204-1 Exception:
• Sec. 11.3 Protection type see Techn. Data
• Sec. 13.2 Identifi cation of conductors

EMC Standards

EN 61000-2-4 Class 3
EN 61000-6-2
EN 61000-6-4 respectively EN 55011 (Tab. 2)
EN 61800-3 Cat.C2 (A1)

Available types

Type
I-TS-3871-600-ol
I-TS-3871-800-ol
I-TS-3871-1000-ol

max. DC voltage in V

600

800

1000

Power in kW

60, 100, 160, 250, 320, 400

100, 160, 250, 320, 400

100, 160, 250, 320, 400, 500

Current in A

  • ± 200
  • ± 600
  • ± 1000
  • ± 200
  • ± 600
  • ± 1000
  • ± 200
  • ± 600
  • ± 1000
  • ± 1200

Current rise time at 0.5x UNenn 10 % - 90 % in ms

< 1,0

< 1,0

< 1,3

Subject to technical changes

We will be happy to check your requirements/specification for feasibility.

Brochure as PDF

Brochure 1200 V, 1200 A as PDF

Learn more!

You want to know more about our products? We will be happy to send you more information by e-mail!