Battery pack / fuel cell / e-Powertrain

DC source/sink

Single-Channel System

I-TS-3842: Single-Channel System – overload

The I-TS-3842 is a single-channel DC source / sink that can be supplemented with selected options.

The I-TS-3842 achieves a measurement accuracy of 0.03 % for voltage and 0.05 % fs for current as standard.

For designs ≥ 1000 V DC, we achieve a voltage rise time of 250 V / ms.

DC-Quelle/Senke Hochleistungs-DC-Test und -Simulation

Our high-performance test system I-TS (Infeed test system) is a high dynamic, bidirectional DC power supply with continuous and seamless transition from source to sink operation. The outstanding performance is the basis for a wide range of applications in the automotive, hydrogen and laboratory sectors.

Safety equipment

Typical applications

Performance hyperbole

Technical data

Type I-TS-3842

AC mains voltage /
AC mains frequency

400 V 3/PE ± 10 %
50 Hz ± 5 %; 60 Hz ± 5 %

Measurement accuracy

Spannung: 0,03 % fs / 16 Bit
Strom: 0,05 % fs / 16 Bit

Control accuracy

Spannung: 0,1 % fs
Strom: 0,1 % fs
Leistung: 0,2 % fs (max. DCW Leistung)

Residual ripple

Voltage ≤ 0.1 % eff. fs
Current ≤ 0.1 % eff. fs

Voltage tolerance dynamic
(0-100 % INom in 3 ms)

Battery tester< 3% fs
Battery emulator < 1% fs

Short circuit performance

Kurzschlussfest:
Anlagen bis 600 A: Icw: 3 kA
Anlagen mit 800 A und 1000 A: Icw: 8 kA
Anlagen mit 1200 A: Icw: 15 kA

Permissible environmental conditions:
Storage as per EN 60721-3-1
Transport as per EN 60721-3-2
Operation as per EN 60721-3-3

1K21 / 1M11, +5 to +40 °C
2K12 / 2M4, -45 to +70 °C
3K22 / 3M11, +5 to +40 °C

Cooling method

air cooling (IP20)
water cooling (IP54)

Safety of machinery -
Safety-related parts of control systems

EN ISO 13849-1
EN ISO 13849-2

Safety of machinery

EN 60204-1 Exception:
• Sec. 11.3 Protection type see Techn. Data
• Sec. 13.2 Identifi cation of conductors

EMC Standards

EN 61000-2-4 class 3
EN 61000-6-2
EN 61000-6-4 bzw.
EN 55011 (Tab. 2)
EN 61800-3 Kat.C2 (A1)

Available types

Typ
I-TS-3842-300-60-600
I-TS-3842-1000-250-1000
I-TS-3842-1200-320-1200
I-TS-3842-1200-550-1200
I-TS-3842-1500-250-800

Nominal power / voltage / current

60 kW / 300 V / 600 A

250 kW / 1000 V / 1000 A

320 kW / 1200 V / 1200 A

550 kW / 1200 V / 1200 A

250 kW / 1500 V / 800 A

Maximum power every 10 minutes for 30 sec.

120 kW

400 kW

420 kW

660 kW

400 kW

Voltage rise time

100 V / ms

250 V / ms

250 V / ms

250 V / ms

250 V / ms

Size

2200 x 800 x 2200 cm
(consisting of 2 cabinets)

2200 x 800 x 2600 cm
(consisting of 2 cabinets)

2200 x 800 x 2600 cm
(consisting of 2 cabinets)

2200 x 800 x 3800 cm
(consisting of 3 cabinets)

On request

Technical specifications subject to change.

(suitable for Rittal cabinets and IP20)

We will be happy to check your requirements/specification for feasibility.

Overview of the different models as PDF